Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Case Report
Case Report, General Medicine
Case Series
Editorial
Editorial Board
Editorial, Hair Transplant
Letter to the Editor, General Medicine
Letter to the Editor, Trichology
Original Article
Original Article, Trichology
Review Article
Review Article, Trichology
Viewpoint, General Medicine
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Case Report
Case Report, General Medicine
Case Series
Editorial
Editorial Board
Editorial, Hair Transplant
Letter to the Editor, General Medicine
Letter to the Editor, Trichology
Original Article
Original Article, Trichology
Review Article
Review Article, Trichology
Viewpoint, General Medicine
View/Download PDF

Translate this page into:

Original Article
1 (
2
); 67-72
doi:
10.25259/JHRRM_8_2026

Innovative smart storage device versus various storage devices for hair grafts: Functions they serve

Department of Plastic Surgery, Harsiddhi Cosmetic & Plastic Surgery Hospital, Surat, Gujarat, India,
Department of Tower Health Program, Reading Hospital, Pennsylvania, United States.

*Corresponding author: Pradipkumar Raghuvirsinh Atodaria, Plastic Surgery, Harsiddhi, Cosmetic & Plastic Surgery Hospital, Surat, 395007, Gujarat, India. dratodaria@gmail.com

Licence
This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-Share Alike 4.0 License, which allows others to remix, transform, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.

How to cite this article: Atodaria PR, Atodaria KP. Innovative smart storage device versus various storage devices for hair grafts: Functions they serve. J Hair Restor Regen Med 2026;1:67-72 doi: 10.25259/JHRRM_8_2026

Abstract

Objectives:

Storage of hair transplant grafts after harvesting and before implantation is a critical step that is often considered passive. However, it involves proper hydration, segregation, total and segregated counting, ergonomic arrangement in chronological order of harvesting, and eventual pickup and implantation using forceps or an implanter following the first-out first-in principle. The objective of this article is to systematically compare the available graft storage devices with respect to the functions they serve and to describe an innovative Smart Storage Device that serves all the ideal functions identified.

Material and Methods:

The available graft storage devices were identified, and their functional characteristics were analyzed. These included: (1) glass or stainless-steel petri-dishes with gauze/Telfa, (2) petri/stainless-steel/plastic dishes without gauze, (3) wooden spatula with gauze, (4) Teflon or similar plates with depressions, and (5) the authors' innovative smart storage device. Each device was evaluated against a set of ideal characteristics identified by the authors, including ability for graft segregation, simultaneous total and individual counting, ergonomic arrangement, individual graft inspection, spacing between grafts, ease of graft pick-up from upper one-third, prevention of dehydration, adherence to first-out first-in chronology, accuracy of graft count, number of staff required, risk of gauze thread contamination, speed of implantation facilitation, quality control in FUT, cooling possibility, and transparency of graft count. The advantages and disadvantages of all devices were tabulated.

Results:

All available devices provide adequate hydration of the grafts. However, the conventional devices — petri-dishes with or without gauze, wooden spatula with gauze, and Teflon plates with depressions — fail to simultaneously address multiple critical functions, including simultaneous total and segregated counting, individual graft inspection, single-handling of grafts, ease of pick-up from the upper one-third, and accurate count of implanted and remaining grafts with a single technician. The innovative smart storage device — made from Teflon or similar material with multiple numbered depressed spaces, each containing 9 partitions, making 10 narrow troughs — fulfills all identified ideal characteristics. It allows one-time handling of grafts by a single technician while achieving simultaneous segregation, total and individual counting, ergonomic arrangement, precision graft inspection, and complete transparency of graft numbers. In FUT cases, individual technicians are allocated separate plates, enabling direct quality control by the surgeon.

Limitations:

Segregation & arranging the grafts in an ergonomic way following the chronological order takes little more time and effort for the technician initially. So there is a small learning curve

Conclusion:

Storage of grafts between harvesting and implantation is a critical and active step that deserves the same attention given to harvesting and implantation techniques. The innovative smart storage device addresses all the ideal characteristics that existing storage devices fail to fulfill simultaneously. It enables simultaneous segregation and total and segregated counting with one-time handling of the grafts by a single technician, ergonomic arrangement in chronological order, precise individual graft inspection, facilitation of implantation speed, quality control in FUT, and complete transparency to the patient. Adoption of this device has the potential to reduce procedure time, staff requirements, graft handling damage, and improve overall outcomes in hair transplantation.

Keywords

First-out first-in
FUE
FUT
Graft counting
Graft storage
Hair transplant grafts
Smart storage device
Storage device

INTRODUCTION

Storage of grafts after harvesting and before implantation is a crucial step that involves proper hydration, segregation, total and segregated counting, ergonomic arrangements in chronological order of harvesting of grafts for storage, pick up, and drop of the grafts for implantation by forceps or an implanter following the first-out first-in principle. Handling the grafts multiple times during this process has the potential risk of damaging the grafts. Due attention should be given to prevent this damage by reducing the handling of the grafts. The likelihood of damage is higher, especially if the grafts are handled in the anatomic lower two-thirds of the graft.[1]

Hair transplantation is a lengthy and tiring procedure for both the team and the patient. A lot has been published on follicular unit excision (FUE) harvesting to improve the graft quality,[2-5] avoiding handling of their lower two-thirds during implantation by “no touch to root technique”,[1] and minimizing damage to scalp vascularity in pre-made slits for improving the result of hair transplant.[6] The articles have been published for time reduction and increasing slit-making precision.[7-9] Less importance is given to the steps between harvesting and implantation, as they are considered passive steps involving storage and preservation of grafts. However, it notably consists of the segregation of grafts according to the number of hairs they contain, total and individual counting, and arranging them ergonomically to help increase the implantation speed while maintaining the hydration of the grafts. The harvested grafts are handled multiple times during these steps, and the principle of handling the grafts from the top or upper one-third may not be strictly followed. Proper handling, storage, and arrangement of the grafts can increase the speed of implantation and improve the quality of resultant transplanted hair growth.

The literature has been published on preservative solutions for the grafts.[10,11]

The reduction in the price of hair transplant procedures globally forces us to reduce the time and effort to perform hair transplantation and decrease the personnel involved to perform the procedure.

MATERIAL AND METHODS

The available graft storage devices were systematically identified, and their functional characteristics were analyzed against a set of ideal characteristics defined by the authors. The following devices were included in the analysis:

  • Petri-Dish/Stainless Steel Dish with Gauze/Telfa: The most common way to store the grafts is by putting them over a gauze or Telfa in glass petri-dishes with or without partitions filled with the storage solution of the surgeon's choice. The harvested grafts are segregated by the number of hairs they contain and put in a bunch of 10 or 20 grafts, arranged in a similar direction and in the chronological order of harvesting. The advantage of this technique is that it helps reduce ischemia time by following the first out and first in technique. It also helps increase the speed of implantation as all the grafts are arranged in the same direction. The task of hair-counting is usually done by the technician using a sterile pencil and paper. This makes the process tiresome and error-prone. This can be avoided if the technician verbally communicates the number of hairs in the graft to a second technician who can do the counting as described above, or use any electronic device. Even the counter used by pathologists for the differential count of white blood cells can be used. The above modification reduces the error but requires an extra person engaged in the procedure. This way of storing grafts prevents dehydration and allows the surgeon to keep track of the grafts implanted and remaining [Figure 1a and b].

  • Stainless steel dish: The glass petri-dishes can be replaced by stainless-steel dishes. It has the advantage of being unbreakable [Figure 1c].

  • Wooden spatula with gauze: A wooden spatula (with or without gauze) has also been used as a storage surface for grafts.

  • Stainless steel or Teflon plates with depressions: Stainless steel or Teflon plates with depressions are also available for storage and segregation [Figure 1d].

  • Color-Coded Dishes: Color-coded dishes have also been used for storage to follow the principle of first out, first in [Figure 1e].

(a and b) Glass or stainless-steel petri-dishes with gauze/Telfa. (c) Petri/stainless-steel/plastic dishes without gauze. (d) Teflon or similar plates with depressions. (e) Different colored dishes for 1 (green dish), 2 (blue dish), 3 (orange dish) and 4 (red dish) hair containing follicles.
Figure 1: (a and b) Glass or stainless-steel petri-dishes with gauze/Telfa. (c) Petri/stainless-steel/plastic dishes without gauze. (d) Teflon or similar plates with depressions. (e) Different colored dishes for 1 (green dish), 2 (blue dish), 3 (orange dish) and 4 (red dish) hair containing follicles.

Storage devices with temperature control for cooling are also available.

Each device was evaluated against the following ideal characteristics defined by the authors for an ideal graft storage device:

  • It should allow the segregation of the 1, 2, 3, and 4 hair-containing grafts.

  • It should allow easy counting and minimize handling of the grafts.

  • It should allow ergonomic arrangement of the grafts.

  • The surgeon should be able to inspect the grafts individually to modify the scoring.

  • The grafts should not stick to the surface and should be easy to pick up from the surface of the storage device.

  • It should prevent dehydration-related damage to grafts.

  • It should facilitate the use of the “first-out, first-in” principle.

  • The surgeon needs to know the speed & quality of grafts cut by the specific technician in the FUT technique, so that the appropriate instructions can be given to the specific technician for improvement.

  • Minimize error and streamline the procedure.

  • It should involve only one technician, reducing the total cost of the procedure.

RESULTS

The advantages and disadvantages of the various devices are outlined in Table 1. For implantation, the technician should pick the grafts using the top or upper third of the graft with forceps and arrange them ergonomically on the scalp close to the implantation site so that they can be implanted quickly and easily. Putting bunched-up grafts will require additional handling of the grafts to separate and arrange them ergonomically. This, in turn, will adversely affect the result of the hair transplantation procedure.

Table 1: Advantages & disadvantages of various devices.
Devices/characteristics Petri-dish / stainless steel dish + gauze Petri / stainless steel / plastic dish without gauze Wooden spatula + gauze Teflon or similar plate with depressions Innovative smart storage device
Segregation of the grafts Yes Yes Yes Yes Yes
Easy simultaneous total & individual counting No No No No Yes
Arrangement in the same direction Yes No Yes Yes Yes
Precise inspection of individual grafts No No Yes No Yes
Spacing between grafts No No Yes No Yes
Ease of pick-up of grafts No No No No Yes
Graft holding only from the upper 1/3rd No No No No Yes
Handling of graft Multiple Multiple Single Multiple Single
Prevention of dehydration Very good Very good Moderate to good Very good Very good
Chronology of first out- first in Perfect Imperfect Perfect Imperfect Perfect
Exact count of implanted & remaining grafts Little difficult Difficult Perfect Difficult Perfect
Number of staff required Two Two Two Two One
Tiny thread of gauze/Telfa in forceps Yes No Yes No No
Helps in increasing the speed of implantation Yes + No Yes + Yes + Yes ++
Quality control in FUT Yes + Difficult Yes ++ Yes + Yes ++
Cooling possible? Yes Yes No No Yes / No
Transparency of the number of hairs/grafts Little difficult Imperfect Little difficult Imperfect Perfect

+/++: Indicates the gradient of usefulness

An innovative device Figure 2 proposed by the authors serves all the above purposes as shown in Figure 3.

Spaces in rows 1 & 2 are for 1 hair graft. Spaces in rows 3, 4, 5 & 6 are for 2 hair grafts. Spaces in rows 7, 8 & 9A are for 3 & 4 hair grafts. Space 9B & 9C ARE for completely transected grafts. Partially transected grafts are put in space C of the respective rows. (1-9 are embossed on left side of the device & indicate rows while A, B & C are embossed on top side of the device indicating columns)
Figure 2: Spaces in rows 1 & 2 are for 1 hair graft. Spaces in rows 3, 4, 5 & 6 are for 2 hair grafts. Spaces in rows 7, 8 & 9A are for 3 & 4 hair grafts. Space 9B & 9C ARE for completely transected grafts. Partially transected grafts are put in space C of the respective rows. (1-9 are embossed on left side of the device & indicate rows while A, B & C are embossed on top side of the device indicating columns)
Photographic documentation for medico-legal & research purposes. Showing the photograph to the patient will increase the credibility & trust for the surgeon. (In this figure- 1,2 & 3 indicates the number of hairs in the follicles. The colors are only used for differentiating purpose)
Figure 3: Photographic documentation for medico-legal & research purposes. Showing the photograph to the patient will increase the credibility & trust for the surgeon. (In this figure- 1,2 & 3 indicates the number of hairs in the follicles. The colors are only used for differentiating purpose)

This device is made from Teflon or a similar material and has multiple numbered depressed spaces having a depth sufficient to submerge the entire graft in the preservative solution of choice. Each space has 9 partitions, making 10 narrow troughs to accommodate 10 grafts in the same direction. The harvested grafts are put separately in different rows, segregated by the number of hairs they contain, in the chronological order they were harvested. The transected grafts are put in 9B & 9C space. This allows the surgeon to inspect all the grafts individually and helps improve further scoring, especially for novice surgeons. The upper part of the space is wide to allow the forceps to pick up the grafts. This arrangement allows easy picking up of the grafts individually or in groups of 3 or 4 to arrange them ergonomically near the recipient site without further handling. All the spaces are interconnected so that all the grafts remain well-hydrated. The number of grafts implanted and the numbers remaining can easily & accurately be counted. In the case of FUT, each cutting technician is allocated a separate plate to be filled with the grafts prepared by them, allowing the surgeon to inspect the grafts. The surgeon can show the arranged harvested grafts in the device to prove the transparency principle of the center.

The proposed device may also be made from stainless steel, titanium, or glass. It may be cooled based on the surgeon's preference.

DISCUSSION

The ideal storage device for the graft should fulfil multiple functional criteria simultaneously. As shown in Table 1. However, each has significant limitations in one or more of the other critical functions.

The most common device — a petri dish with gauze — provides good hydration and follows the first-out first-in principle but requires two technicians and makes simultaneous total and individual counting difficult. The wooden spatula with gauze permits single handling and precise inspection of individual grafts, but does not allow cooling, and the gauze threads can inadvertently contaminate the forceps. Teflon or similar plates with depressions have multiple advantages but make exact counting difficult and do not allow graft inspection or holding from the upper one-third.

The innovative smart storage device addresses all these limitations in a single device. The key advantage over all existing devices is its ability to allow simultaneous total and segregated counting of grafts with a single handling by one technician. The numbered and partitioned depressed spaces allow each graft to be individually visible, inspectable, and easily picked up from the upper one-third, directly reducing graft damage. The chronological arrangement in numbered spaces perfectly implements the first-out first-in principle and enables accurate counting of implanted and remaining grafts at any point during the procedure.

In FUT procedures, the allocation of individual plates to each cutting technician introduces a quality control mechanism that is not possible with conventional devices. The surgeon can directly assess the quality and transection rate of each technician in real time and provide corrective instructions immediately.

The transparency feature of the smart storage device — allowing the patient to see the total and segregated graft count — is a novel and clinically relevant benefit. It builds patient confidence and trust, and supports the growing demand for procedural transparency in cosmetic practice.

LIMITATIONS

Segregation & arranging the grafts in an ergonomic way following the chronological order takes little more time and effort for the technician initially. So there is a small learning curve

CONCLUSION

Storage of grafts after harvesting and before implantation a critical step. It involves proper hydration, counting, segregation, arrangement for storage, and eventual implantation using either forceps or implantation devices. The grafts can suffer inadvertent damage during these steps. The new device helps in simultaneous segregation and total & segregated counting with one-time handling of the grafts by a single technician easily & accurately. It also helps in an ergonomic arrangement of the grafts in chronological order of their harvesting, with minimum handling to facilitate implantation. More importantly, it allows the surgeon to have a precise look at the harvested grafts to make fine adjustments in scoring for better quality graft harvesting. The patient can see the quality of grafts with segregated & total number in the proposed device, will definitely appreciate the transparency & trust the surgeon more than ever.

Disclosure:

The innovative device by the authors is registered under a patent.

Author contributions:

PRA: Study design, innovation, data collection & manuscript writing; KPA: Innovation & manuscript writing.

Ethical approval:

Institutional Review Board approval is not required as this article describes an innovative device concept and a comparative analysis of graft storage devices. No clinical study involving human subjects or animals was conducted for the purpose of this article.

Declaration of patient consent:

Patient's consent is not required as patients’ identity is not disclosed or compromised.

Conflicts of interest:

The innovative device by the author is registered under a patent.

Use of artificial intelligence (AI)-assisted technology for manuscript preparation:

The authors confirm that there was no use of artificial intelligence (AI)-assisted technology for assisting in the writing or editing of the manuscript and no images were manipulated using AI.

Financial support and sponsorship: Nil.

References

  1. , . Hair Transplantation: A brief review. Clin Dermatol Rev. 2022;6:80-7.
    [CrossRef] [Google Scholar]
  2. , , , . Follicular Unit extraction hair transplant harvest: A review of current recommendations and future considerations. Dermatol Online J. 2014;20 Available from: https://escholarship.org/uc/item/1954f4vv [Last accessed on 2026 Apr 14]
    [CrossRef] [PubMed] [Google Scholar]
  3. , , , , . Establishment And clinical application of the concept of invalid extraction rates in follicular unit extraction. Clin Cosmet Investig Dermatol. 2021;14:225-9.
    [CrossRef] [PubMed] [Google Scholar]
  4. , . Follicular Unit extraction hair transplant. J Cutan Aesthet Surg. 2010;3:76-81.
    [CrossRef] [PubMed] [Google Scholar]
  5. , . Donor Harvesting: Follicular unit excision. J Cutan Aesthet Surg. 2018;11:195-201.
    [Google Scholar]
  6. . An Innovative instrument for reducing the surgeon's time in making recipient sites. Hair Transplant Forum Int. 2014;24:131-2.
    [CrossRef] [Google Scholar]
  7. , . Modifications Of multi slit knife for enhanced versatility in balding and vertex area hair transplant. J Cutan Aesthet Surg. 2020;13:247-50.
    [CrossRef] [PubMed] [Google Scholar]
  8. , . Reducing Surgical time: An innovative and versatile instrument for creating multiple brick-pattern sagittal recipient sites in a single stroke. Hair Transplant Forum Int. 2020;30:180-1.
    [CrossRef] [Google Scholar]
  9. , . The Optimal holding solution and temperature for graft grafts. Hair Transplant Forum Int. 2012;22:17-21.
    [CrossRef] [Google Scholar]
  10. . Bio-enhanced Hair restoration. Hair Transplant Forum Int. 2014;24:121-30.
    [CrossRef] [Google Scholar]
  11. , , , . Optimal Hair transplant recipient site slit design: Minimizing vascular damage. Indian J Plast Surg. 2021;54:471-6.
    [CrossRef] [PubMed] [Google Scholar]